Preview: check roof-data availability by address. Sample reports use synthetic data.Payments are in test mode.Read the sample report

Skip to main content
All sample reports
Sample property

Metal Roof Package

Standing-seam panel schedule, layout, cut list, trim, clips, thermal movement and metal bill of materials.

4100 Example Ridge Drive, Plano, TX 75024 (synthetic). Made-up example data, not a measurement of a real home.

RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Standing-seam metal package

Metal Roof Package

4100 Example Ridge Drive, Plano, TX 75024

Panels
369
16 in coverage
Net coverage
5,125 sq ft
roof area under panels
Cut waste
325 sq ft
rip 78 · taper 248
Trim
999 LF
143 stock pieces
Clips
3,362
sample pattern only
Three-dimensional view of the roof with 369 standing-seam panels drawn on 17 facets.
Standing seams at 16 in centres on the 3D roof model, viewed from the south-west. Walls are drawn for context only.

Selected panel system

System
Sample 16 in snap-lock standing seam
Profile
Snap-lock standing seam, 1.5 in seam, striated pan
Coverage and gauge
16 in · 24 ga
Material
Galvalume-coated steel (sample)
Selected finish
Kynar-style PVDF, Charcoal Gray
Panel lengths
Cut to length to the nearest 1 in, up to 40 ft
Values
Preset, not yet reviewed
Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 1 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Layout

Panel layout plan

4100 Example Ridge Drive, Plano, TX 75024

Plan of the standing-seam layout: 369 panels over 17 facets, each facet numbered to match the panel schedule.1234567891011121314151617
Seams at 16 in centres. Numbers match the panel schedule; arrows run up each panel from eave to ridge.
  • Standing seam, 16 in on centre
  • Metal panels

Layout key · facets 1–6

#FacesPanelsStarts at
1N18Centred
2N48Centred
3N20E end
4W30N end
5E30S end
6E20S end

Layout key · facets 7–12

#FacesPanelsStarts at
7N23Centred
8S20W end
9S53Centred
10W8Centred
11E8Centred
12W8Centred

Layout key · facets 13–17

#FacesPanelsStarts at
13E8Centred
14S28Centred
15W17N end
16E17S end
17S13Centred

Each facet's layout starts at its left end, seen from the eave looking up the slope; a partial panel falls at the right-hand end. Where that end panel would be narrower than the system's minimum rip, the layout is centred so both end panels are ripped equally.

Every panel is a rectangle cut to the longest extent of its strip. Tapers at hips and valleys and notches around openings are cut on site and counted as cut waste.

Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 2 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Panels

Panel schedule

4100 Example Ridge Drive, Plano, TX 75024

Panels
369
16 in coverage
Net coverage
5,125 sq ft
roof area under panels
Cut waste
325 sq ft
rip 78 · taper 248
Trim
999 LF
143 stock pieces
Clips
3,362
sample pattern only

17 facets · 369 panels

#PitchArea sq ftEave → ridgePanelsRip widthOrdered LFCut waste sq ft
13/1227211' 10"189 3/4 in216.012
27/1286622' 9"4810 3/8 in693.346
36/1228914' 8"2011 in232.116
47/1244922' 9"308 1/2 in365.430
57/1244922' 9"308 1/2 in365.430
66/1219314' 8"2011 in163.520
76/1248716' 6"239 1/8 in383.319
86/1228914' 8"2011 in228.110
97/1263822' 9"5310 3/8 in543.576
108/12303' 11"88 1/2 in28.25
118/12303' 11"88 1/2 in28.25
128/12303' 11"88 1/2 in28.25
138/12303' 11"88 1/2 in28.25
146/1253616' 6"288 1/2 in420.820
159/1219912' 4"1714 in159.310
169/1219912' 4"1714 in157.98
174/121428' 8"1310 3/8 in114.88
Total5,1253694,156.2325

Panels cover 5,125 sq ft of roof; 5,542 sq ft of panel is ordered. The difference is cut waste (rip 78 sq ft at ripped end panels, taper 248 sq ft at hips, valleys and openings) plus hems, laps and rounding each length up to the inch.

Eave → ridge is the facet’s true slope length. Ordered LF includes the eave hem, end laps and rounding; it adds up to the cut list.

Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 3 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Cut list

Panel cut list

4100 Example Ridge Drive, Plano, TX 75024

Panels
369
Ordered length
4,156 LF
Distinct cuts
96
length and width
Longest panel
22' 11"
within the 40 ft limit

Cuts, longest first · part 1 of 3

LengthInchesWidthCountTotal LFFacets
22' 11"275 inFull 16 in16366.72, 4, 5
22' 10"274 inFull 16 in245.79
22' 9"273 inFull 16 in491.02, 9
22' 7"271 inFull 16 in245.24, 5
21' 9"261 inFull 16 in243.54, 5
21' 3"255 inFull 16 in242.52
21' 1"253 inFull 16 in484.34, 5, 9
20' 3"243 inFull 16 in240.54, 5
19' 8"236 inFull 16 in239.32
19' 6"234 inFull 16 in239.04, 5
19' 1"229 inFull 16 in238.29
18' 8"224 inFull 16 in237.34, 5
18' 2"218 inFull 16 in236.32
18' 0"216 inFull 16 in236.04, 5
17' 2"206 inFull 16 in234.34, 5
17' 1"205 inFull 16 in234.29
16' 8"200 inFull 16 in43716.77, 14
16' 8"200 inRip 9 1/8 in233.37
16' 8"200 inRip 8 1/2 in116.714
16' 7"199 inFull 16 in116.62
16' 5"197 inFull 16 in232.84, 5
15' 7"187 inFull 16 in231.24, 5
15' 2"182 inFull 16 in230.39
15' 1"181 inFull 16 in345.32, 9
14' 10"178 inFull 16 in23341.23, 4, 5, 6, 8
14' 10"178 inRip 11 in114.83
14' 7"175 inFull 16 in229.26, 8
14' 1"169 inFull 16 in228.24, 5
13' 7"163 inFull 16 in227.23, 6
13' 6"162 inFull 16 in454.02, 9
13' 4"160 inFull 16 in226.74, 5
13' 2"158 inFull 16 in226.39
13' 1"157 inFull 16 in226.26, 8
12' 6"150 inFull 16 in16200.04, 5, 15, 16

Continued on next page →

Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 4 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Cut list

Panel cut list (continued)

4100 Example Ridge Drive, Plano, TX 75024

Cuts, longest first · part 2 of 3

LengthInchesWidthCountTotal LFFacets
12' 6"150 inRip 14 in112.515
12' 5"149 inFull 16 in224.89
12' 4"148 inFull 16 in112.316
12' 1"145 inFull 16 in224.23, 6
12' 0"144 inFull 16 in20240.01, 2, 9
12' 0"144 inRip 9 3/4 in224.01
11' 9"141 inFull 16 in223.54, 5
11' 8"140 inFull 16 in111.715
11' 7"139 inFull 16 in334.86, 8, 16
11' 5"137 inFull 16 in111.42
11' 2"134 inFull 16 in222.39
11' 0"132 inFull 16 in222.04, 5
10' 7"127 inFull 16 in221.23, 6
10' 5"125 inFull 16 in552.12, 9, 15
10' 3"123 inFull 16 in330.84, 5, 16
10' 2"122 inFull 16 in220.36, 8
9' 5"113 inFull 16 in218.84, 5
9' 2"110 inFull 16 in19.29
9' 1"109 inFull 16 in545.43, 6, 9, 15
8' 11"107 inFull 16 in544.62, 9, 16
8' 10"106 inFull 16 in1197.217
8' 10"106 inRip 10 3/8 in217.717
8' 8"104 inFull 16 in434.74, 5, 6, 8
7' 11"95 inFull 16 in215.84, 5
7' 10"94 inFull 16 in17.815
7' 8"92 inFull 16 in17.716
7' 7"91 inFull 16 in215.23, 6
7' 6"90 inFull 16 in430.014
7' 6"90 inRip 8 1/2 in17.514
7' 4"88 inFull 16 in429.32, 9
7' 2"86 inFull 16 in428.74, 5, 6, 8
7' 0"84 inFull 16 in17.02
6' 7"79 inFull 16 in532.92, 9
6' 6"78 inFull 16 in16.515
6' 5"77 inFull 16 in212.89
6' 4"76 inFull 16 in319.04, 5, 16
6' 2"74 inFull 16 in212.33, 6

Continued on next page →

Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 5 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Cut list

Panel cut list (continued)

4100 Example Ridge Drive, Plano, TX 75024

Cuts, longest first · part 3 of 3

LengthInchesWidthCountTotal LFFacets
5' 10"70 inFull 16 in423.32, 9
5' 8"68 inFull 16 in211.36, 8
5' 7"67 inFull 16 in211.24, 5
5' 3"63 inFull 16 in15.315
5' 1"61 inFull 16 in210.22, 16
4' 10"58 inFull 16 in29.74, 5
4' 8"56 inFull 16 in29.33, 6
4' 3"51 inFull 16 in417.02, 9
4' 2"50 inFull 16 in28.36, 8
4' 1"49 inFull 16 in1873.54, 5, 10, 11, 12, 13
4' 1"49 inRip 8 1/2 in416.310, 11, 12, 13
3' 11"47 inFull 16 in13.915
3' 9"45 inFull 16 in13.816
3' 7"43 inFull 16 in414.310, 11, 12, 13
3' 3"39 inFull 16 in26.54, 5
3' 2"38 inFull 16 in26.33, 6
2' 8"32 inFull 16 in718.72, 6, 8, 9, 15
2' 6"30 inFull 16 in37.54, 5, 16
2' 2"26 inFull 16 in48.710, 11, 12, 13
2' 1"25 inFull 16 in816.79
2' 0"24 inFull 16 in510.03, 4, 5, 6, 15
2' 0"24 inRip 14 in12.016
2' 0"24 inRip 11 in24.06, 8
2' 0"24 inRip 10 3/8 in48.02, 9
2' 0"24 inRip 8 1/2 in612.04, 5, 10, 11, 12, 13
Total3694,156.2

Lengths include a 1 1/2 in hem where a panel starts at an eave. A run longer than the longest panel is split into equal panels end-lapped 6 in (none on this roof). Panels shorter than 2' 0" are ordered at that minimum.

Ripped panels are ordered full width and ripped on site. Offcuts are not assumed reusable; any reuse is the installer’s saving, not a planned quantity.

Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 6 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Trim

Trim schedule

4100 Example Ridge Drive, Plano, TX 75024

Trim, net
999 LF
With +10%
1,098 LF
Stock pieces
143
counted run by run
Selected gauge, finish
24 ga
Kynar-style PVDF, Charcoal Gray
TrimBlankNet LF+10%StockLapRunsPiecesNotes
Ridge cap20 in103.7114.010 ft4 in616Over Z-closures
Hip cap20 in159.8175.810 ft4 in622Over Z-closures
Eave drip / gutter apron8 in403.3443.610 ft2 in1854Cleated; panels hem over
Rake / gable trim10 in113.0124.410 ft2 in1218Cleated, 3 in face
W-valley pan24 in57.162.810 ft6 in68Open valley
Sidewall flashing12 in96.8106.410 ft4 in1115Counter-flashed at wall
Headwall / apron flashing14 in65.071.510 ft4 in710Over Z-closures
Total998.61,098.566143

Trim location key

  • Ridge cap103.7 LF
  • Hip cap159.8 LF
  • Eave drip / gutter apron403.3 LF
  • Rake / gable trim113.0 LF
  • W-valley pan57.1 LF
  • Sidewall flashing96.8 LF
  • Headwall / apron flashing65.0 LF
Plan of the roof with each line coloured by its trim type, matching the trim schedule.
Trim location key: every line is drawn in the colour and pattern of the trim it takes.

Each straight run of one trim type is extended by 10% for cutting and counted in stock pieces with its laps; runs are never pooled and divided by the stock length. Lines where a withheld facet meets a laid one are included; skylight curbs take the skylight maker's kit.

Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 7 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Attachment

Clips and fasteners

4100 Example Ridge Drive, Plano, TX 75024

Clips by facet and zone

#CornerPerimeterFieldClipsScrews
1308448162324
2762761725241,048
33911045194388
46017760297594
56017760297594
6608611157314
727161100288576
83810944191382
976217134427854
10151703264
11151703264
12151703264
13151703264
1442178104324648
15277932138276
16277932138276
1715523097194
Total6371,8538723,3626,724

Attachment pattern

Clip
Sample sliding clip
Perimeter lines
eave, rake, ridge, hip
Zone widths
Perimeter 4.0 ft; corner 4.0 ft
  • Pattern: Sample engineering pattern — for demonstration only
  • Source: Invented for the sample report. Not engineered for any site, wind speed, exposure or deck.
  • Substrate: 15/32 in plywood deck (assumed for the sample)
  • Clip spacing: Corner 12 in · perimeter 16 in · field 24 in
  • Fasteners: 2 per clip, #10 × 1 in pancake-head screw
Plan of the attachment zones used for the clip counts, with facets numbered.1234567891011121314151617
Dashed: the inner edge of the 4.0 ft perimeter zone along eave, rake, ridge, hip lines. Corners are where two bands cross; the field is inside.

Clips are counted along each panel's centre line: one at the low end, then as many as keep every gap within the spacing of the zone the gap lies in. Zones are measured in the roof plane from the pattern's perimeter lines; corners are where two perimeter bands meet.

Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 8 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Thermal movement

Thermal movement

4100 Example Ridge Drive, Plano, TX 75024

Movement at the free end of the longest run

#RunsLongest runMovementStatus
11811' 10"0.16 inWithin clip travel
24822' 9"0.31 inWithin clip travel
32014' 8"0.20 inWithin clip travel
43022' 9"0.31 inWithin clip travel
53022' 9"0.31 inWithin clip travel
62014' 8"0.20 inWithin clip travel
72316' 6"0.23 inWithin clip travel
82014' 8"0.20 inWithin clip travel
95322' 9"0.31 inWithin clip travel
1083' 11"0.05 inWithin clip travel
1183' 11"0.05 inWithin clip travel
1283' 11"0.05 inWithin clip travel
1383' 11"0.05 inWithin clip travel
142816' 6"0.23 inWithin clip travel
151712' 4"0.17 inWithin clip travel
161712' 4"0.17 inWithin clip travel
17138' 8"0.12 inWithin clip travel

Thermal inputs

Expansion coefficient
6.7 × 10⁻⁶ per °F
Design temperature swing
170 °F
Clip travel
0.63 in
Largest movement
0.31 in
Runs over the travel
0
  • Fixed point: Pinned at the ridge; the eave end moves

Movement = expansion coefficient × free length × design temperature swing, taken from each run’s true length. The fixed point and clip travel come from the system design; a run over the travel needs a mid-length fixed point, a longer-travel clip or a break in the run.

Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 9 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Bill of materials

Metal bill of materials

4100 Example Ridge Drive, Plano, TX 75024

ItemQuantityUnitBasis
Panels
Standing-seam panels, 16 in, 24 ga369panels4,156 LF, 5,542 sq ft ordered; lengths in the cut list
Trim and flashing
Ridge cap, 10 ft16pieces104 LF + 10% over 6 runs, 4 in laps
Hip cap, 10 ft22pieces160 LF + 10% over 6 runs, 4 in laps
Eave drip / gutter apron, 10 ft54pieces403 LF + 10% over 18 runs, 2 in laps
Rake / gable trim, 10 ft18pieces113 LF + 10% over 12 runs, 2 in laps
W-valley pan, 10 ft8pieces57 LF + 10% over 6 runs, 6 in laps
Sidewall flashing, 10 ft15pieces97 LF + 10% over 11 runs, 4 in laps
Headwall / apron flashing, 10 ft10pieces65 LF + 10% over 7 runs, 4 in laps
Accessories
Panel-end Z-closure, 16 in37packs of 10368 panel ends at ridges, hips and headwalls
High-temperature synthetic underlayment6rolls5,125 sq ft + 10% laps, 1,000 sq ft a roll
#10 × 1 in pancake-head screw5boxes of 2501,098 LF of trim at 12 in = 1,099 screws
Butyl tape, 1 in × 45 ft28rollsOne roll per 40 LF of trim (1,098 LF)
Clips and clip fasteners
Sample sliding clip3,362clipsZones: 637 corner, 1,853 perimeter, 872 field
#10 × 1 in pancake-head screw27boxes of 2503,362 clips × 2 = 6,724 screws
Penetrations
Pipe flashing boots for standing seam3eachPlumbing vents on metal facets; pipe sizes not measured
Vent flashing kits3eachExhaust and box vents on metal facets; one kit each
Skylight curb flashing kits2kitsOne per skylight, from the skylight maker
Not assessed in this package
Chimney cricket and counter-flashingNot assessed—1 chimney; made on site to fit, not quantified
Snow retentionNot assessed—Depends on climate, code and the snow-guard layout
Ridge ventilation and vented closuresNot assessed—Sized by the ventilation add-on, not here

Quantities come from the panel schedule, cut list and trim schedule on the previous pages and reconcile to them; accessory rules are the selected system preset’s, printed on the references page.

3 lines have no quantity; their reason is in the basis column. An absent quantity is never counted as zero.

Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 10 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Metal package · Scope

Scope, assumptions and references

4100 Example Ridge Drive, Plano, TX 75024

Panel system

System
Sample 16 in snap-lock standing seam
Profile
Snap-lock standing seam, 1.5 in seam, striated pan
Coverage and seam
16 in coverage, 1 1/2 in seam
Gauge and material
24 ga Galvalume-coated steel (sample)
Selected finish
Kynar-style PVDF, Charcoal Gray
Minimum slope
3/12
Panel lengths
Cut to length to the nearest 1 in, up to 40 ft
Review
Not reviewed: preset values
  • Allowances: 1 1/2 in eave hem, 6 in end lap, 2' 0" minimum length, 6 in minimum rip
  • Source: Sample preset for demonstration: values typical of published 16 in snap-lock literature. Not a manufacturer data sheet.

Package inputs

Trim allowance
10% on each run
Closures
Panel-end Z-closure, 16 in, packs of 10
Trim fasteners
#10 × 1 in pancake-head screw at 12 in
Sealant
Butyl tape, 1 in × 45 ft, one roll per 40 ft of trim
Thermal design
170 °F swing, clip travel 0.63 in
Calculation
metal-package-v1
  • Underlayment: High-temperature synthetic underlayment; 1,000 sq ft rolls, 10% laps
  • Attachment pattern: Sample engineering pattern — for demonstration only. Invented for the sample report. Not engineered for any site, wind speed, exposure or deck.

Reconciliations run on this package

Package checkResultDetail
Panel counts reconcilePassed369 panels in the schedule, 369 in the cut list, 369 on the bill of materials.
Ordered length reconcilesPassedCut-list feet equal the ordered length of every run, hems and laps included.
Coverage equals the roof areaPassedPanels cover 5,125 sq ft against 5,125 sq ft of laid facets.
Trim lengths equal the measured linesPassedEvery trim row sums the same classified lines as the roof report totals.
Facets laidPassedEvery facet in scope has a panel layout.
Clips from an approved patternNoteCounted from "Sample engineering pattern — for demonstration only".
Thermal movement within clip travelPassedNo run moves more than the clip travel.

Verify before ordering

  • Confirm the panel system, gauge, finish and colour with the supplier; this package prints the selection, not the existing roof.
  • Field-measure every run before lengths are released to the roll-former; lengths here come from the roof model, not a tape.
  • Confirm the deck, the approved attachment pattern and the design wind inputs for the site.
  • Check eaves, rakes and walls: gutters, fascia, cladding and chimney flashings change trim profiles.
  • The manufacturer's current installation instructions govern over any sequence or detail implied here.

Not included

  • Prices, labour, tear-off and disposal.
  • Structural adequacy, uplift design and code compliance.
  • Snow retention, ventilation and gutters, which have their own reports.
  • Custom flashings at chimneys and curbs beyond the kit counts.
  • Offcut reuse, which is never assumed.
Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 11 of 12
RoofKarmaMetal Roof Package
RK-2026-0925-S4R1-R7 · v1Sample — synthetic property

Sources and limitations

Evidence, checks and limitations

4100 Example Ridge Drive, Plano, TX 75024

This report

Report
RK-2026-0925-S4R1-R7 · v1
Generated
Sep 25, 2026
Measurement grade
A — Sample grade
Imagery date
Mar 1, 2026
Geometry
RoofKarma synthetic massing model (roof-build v1)
Calculation
roof-analysis v1 · complexity-policy-v1
Template
report-book@1 · R7
Metal package
metal-package-v1 · sample-snap-lock-16

Why this grade

Shown as grade A to demonstrate a complete report. A real report is graded from its source quality, obstruction and automated checks; grade D withholds prices and orderable quantities.

Automated quality checks

Automated checkResultDetail
Every facet closesPassedAll 17 facets are closed planar polygons.
Every line is classifiedPassedNo unclassified line; each is an eave, rake, ridge, hip, valley or flashing line.
Shared lines counted oncePassedRidges, hips and valleys shared by two facets are single lines in every total.
Pitch within 0/12 to 24/12PassedEvery facet pitch is within the modelled range.
Totals recompute exactlyPassedFacet areas sum to 5,125 sq ft before display rounding.
Structures in scopeNoteDetached workshop not included in totals (selectable).
SourceNoteSynthetic sample geometry. A real report states its imagery source, date and quality here.

Check at the property

  • Confirm valley and wall-flashing lengths where lower roofs meet walls.
  • Check chimney and skylight flashing condition and whether kits will be replaced.
  • Count vents and pipe boots; the drawing shows what is visible from above.
  • Confirm tear-off layers and decking before finalising the order.

Limitations

  • Every figure in this sample comes from an invented house built to exercise the report; it is not a surveyed property.
  • Measurements come from above: wall heights, decking condition and the number of layers are not visible from the air.
  • No accuracy or certification is claimed; a roofer confirms quantities on site before ordering.
Synthetic sample. Not a measurement of a real property.RoofKarma · Metal Roof PackagePage 12 of 12