Blueprint Takeoff
A roof measured from a calibrated plan set, with sheet references and a revision lock.
Lot 14, Example Ranch Estates, Prosper, TX 75078 (synthetic plan set, planned, not built). Made-up example data, not a measurement of a real home.
Blueprint takeoff
Blueprint Takeoff
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
- Planned roof area
- 4,443 sq ft
- Squares
- 44.43
- Roof facets
- 10
- Predominant pitch
- 8/12
- from elevation notes
- Calibration agreement
- 0.14%
- within 0.5% tolerance
Plan set
- Project
- Lot 14, Example Ranch Estates, Prosper, TX 75078
- Status
- Planned, not built
- Plan set
- Example Ranch Estates — Plan 2410 (synthetic plan set)
- Sheets
- A-101 rev C, A-201 rev C, A-501 rev B
- Revision lock
- RL-E96247DC
In this report
- Drawing register and calibration2
- Roof diagram3
- Roof wireframe4
- Roof anatomy & measurement guide5
- Length measurement report6
- Area measurement report7
- Pitch and direction8
- Facet ledger9
- Roof summary and waste10
- Material estimate11
- Edge ledger14
- Scope, revision and source notes16
Plan set
Drawing register and calibration
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
- Planned roof area
- 4,443 sq ft
- Squares
- 44.43
- Roof facets
- 10
- Predominant pitch
- 8/12
- from elevation notes
- Calibration agreement
- 0.14%
- within 0.5% tolerance
Drawing register
| Sheet | Title | Scale as printed | Rev | Date | Used for |
|---|---|---|---|---|---|
| A-101 | Roof plan | 1/8" = 1'-0" | C | Aug 14, 2026 | Roof outline traced; scale calibrated |
| A-201 | Exterior elevations | 1/8" = 1'-0" | C | Aug 14, 2026 | Pitch notes, eave heights |
| A-501 | Roof details | 3/4" = 1'-0" | B | Jul 2, 2026 | Referenced for details; nothing measured from it |
Scale calibration: two independent printed dimensions
| Dimension | Sheet | Printed | On sheet | Scale | At adopted | Deviation |
|---|---|---|---|---|---|---|
| CAL-1 · Overall depth along the west wall | A-101 | 40' 0" | 5.004 in | 1 in = 7.994 ft | 40' 0" | +0.07% |
| CAL-2 · Garage width across the door wall | A-101 | 28' 0" | 3.498 in | 1 in = 8.005 ft | 28' 0" | −0.07% |
Scale comes only from printed dimensions measured on the traced sheet. A title-block scale note or an image resolution is recorded, never used; each sheet is calibrated on its own.
Result
- Status
- Accepted — measurement allowed
- Adopted scale
- 1 in = 7.999 ft
- Agreement
- 0.14% (tolerance 0.50%)
Revision lock
- Lock
- RL-E96247DC
- Calibration digest
- 663f65e7
- Sheets: A-101/C@2026-08-14 A-201/C@2026-08-14 A-501/B@2026-07-02
The lock is built from each sheet id, revision and date plus a digest of the calibration. A superseded sheet or a new calibration changes it, and that produces a new report version.
Plan sheet A-101 rev C · Diagram
Roof diagram
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
Structures
- Planned house and garage4,443 sq ft
Roof features: count on site
| Feature | Count on site | Size or note |
|---|---|---|
| Chimneys | ||
| Skylights | ||
| Plumbing vents | ||
| Exhaust and box vents | ||
| Other (dish, HVAC unit, solar) |
This source does not detect roof features, so none is drawn or counted here and none is assumed absent. Fill this list in on site.
Plan sheet A-101 rev C · Roof structure · retained geometry
Roof wireframe
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
Read the same retained roof in plan and 3D. Colors and line patterns identify the model’s edge classes.
Classes in this model
- Eaves
- Rakes
- Ridges
- Hips
- Valleys
- Step flashing
- Wall flashing
Read the model
The plan and oblique drawing use the same roof geometry. The next page explains the line types and how to read measurements.
Drawings use the retained roof model. Concealed details remain unknown.
Openings remain holes. Context walls are illustrative unless separately surveyed. Check dimensions and uncertain boundaries on site.
Calibrated plan geometry: planned dimensions, not an as-built survey.
Plan sheet A-101 rev C · Understand your roof
Roof anatomy & measurement guide
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
These names explain the edge classes present in this model. A missing class is not proof that the feature is absent on the building.
Read the wireframe colors and patterns
| Model class | What it means |
|---|---|
| Eaves | Lower, usually level boundary where a roof plane drains. |
| Rakes | Sloping outer edge along a gable. |
| Ridges | High meeting line between adjacent roof planes. |
| Hips | Outward sloping junction between roof planes. |
| Valleys | Inward junction that channels water between roof planes. |
| Step flashing | Sloping roof-to-wall junction; flashing installation needs inspection. |
| Wall flashing | Roof-to-wall junction across the top of a roof plane. |
Area and openings
Roof surface area follows each slope; plan area is its horizontal footprint. The two can differ.
Only recorded geometric openings are deducted. Equipment or an unseen penetration is not automatically a hole.
Lengths and pitch
Line lengths follow the 3D endpoints. Shared roof lines are counted once. Do not measure an oblique drawing with a ruler.
Pitch is vertical rise per 12 horizontal units. Display rounding does not change the stored geometry.
Drawings use the retained roof model. Concealed details remain unknown.
Openings remain holes. Context walls are illustrative unless separately surveyed. Check dimensions and uncertain boundaries on site.
Calibrated plan geometry: planned dimensions, not an as-built survey.
Plan sheet A-101 rev C · Lengths
Length measurement report
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
- Eaves261' 6"
- Rakes112' 11"
- Ridges66' 9"
- Hips123' 1"
- Valleys46' 0"
- Step flashing9' 6"
- Wall flashing42' 0"
- Transitions0' 0"
- Parapet walls0' 0"
Labels show true 3D lengths rounded to the nearest foot. Totals above are summed unrounded and rounded once to the inch.
Flashing lines are drawn dotted. 5 short or crowded lines are not labelled here; every line is listed in the edge ledger.
Plan sheet A-101 rev C · Areas
Area measurement report
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
- Total roof area
- 4,443 sq ft
- Squares
- 44.43
- Pitched roof area
- 4,443 sq ft
- Low-slope area (below 2/12)
- 0 sq ft
- Predominant pitch
- 8/12
- Predominant pitch area
- 3,848 sq ft
- Upper-story area
- 0 sq ft
- Roof facets
- 10
Areas are sloped (true surface) square feet, rounded to the nearest whole number on the drawing. The totals are sums of the unrounded facet areas.
No opening is drawn on this roof, so nothing is deducted for one; roof-mounted equipment is not deducted.
Plan sheet A-101 rev C · Pitch and direction
Pitch and direction
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
Area by pitch
Steepness
- 2/12 – 3/12
- 8/12 – 9/12
- 10/12 – 11/12
Pitch is shown to the nearest whole rise over 12; areas and classes use the unrounded pitch. Arrows point down the slope, the way water runs.
Plan sheet A-101 rev C · Facets
Facet ledger
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
Facets 1–10 of 10
| # | Level | Pitch | Faces | Area sq ft | % roof |
|---|---|---|---|---|---|
| 1 | Main | 3/12 | N | 294 | 6.6% |
| 2 | Main | 8/12 | N | 1,057 | 23.8% |
| 3 | Main | 8/12 | W | 481 | 10.8% |
| 4 | Main | 8/12 | E | 452 | 10.2% |
| 5 | Main | 8/12 | S | 982 | 22.1% |
| 6 | Main | 8/12 | E | 471 | 10.6% |
| 7 | Main | 8/12 | W | 406 | 9.1% |
| 8 | Main | 10/12 | W | 95 | 2.1% |
| 9 | Main | 10/12 | E | 95 | 2.1% |
| 10 | Main | 3/12 | S | 111 | 2.5% |
Plan sheet A-101 rev C · Summary
Roof summary and waste
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
Measurements
- Total roof area
- 4,443 sq ft
- Squares
- 44.43
- Pitched area
- 4,443 sq ft
- Low-slope area
- 0 sq ft
- Footprint (plan) area
- 3,743 sq ft
- Roof facets
- 10
- Predominant pitch
- 8/12
- Pitch range
- 3/12 – 10/12
- Stories
- 1
- Complexity
- Moderate · 45 of 100
- Recommended waste
- 12%
Roof lines
| Line type | Lines | Length |
|---|---|---|
| Eaves | 15 | 261' 6" |
| Rakes | 10 | 112' 11" |
| Ridges | 3 | 66' 9" |
| Hips | 4 | 123' 1" |
| Valleys | 4 | 46' 0" |
| Step flashing | 3 | 9' 6" |
| Wall flashing | 2 | 42' 0" |
| Transitions | 0 | 0' 0" |
| Parapet walls | 0 | 0' 0" |
| Hips + ridges | 7 | 189' 10" |
| Eaves + rakes | 25 | 374' 5" |
| All flashing | 5 | 51' 6" |
Area by pitch
| Pitch | 8/12 | 3/12 | 10/12 |
|---|---|---|---|
| Area (sq ft) | 3,848 | 405 | 189 |
| Squares | 38.48 | 4.05 | 1.89 |
| Share | 87% | 9% | 4% |
Waste scenarios
| Waste | 0% | 5% | 10% | Recommended12% | 15% | 17% | 20% | 25% |
|---|---|---|---|---|---|---|---|---|
| Area (sq ft) | 4,443 | 4,665 | 4,887 | 4,976 | 5,109 | 5,198 | 5,331 | 5,553 |
| Squares | 44.43 | 46.65 | 48.87 | 49.76 | 51.09 | 51.98 | 53.31 | 55.53 |
0% is net measured area. Other columns include the stated waste. Squares are decimal area (100 sq ft each), not rounded purchase quantities.
Recommended 12% for asphalt shingles: moderate roof, 45 of 100 points (10 facets, 4 valleys, 4 hips, 3 pitches, 91% of area at 7/12 or steeper). Penetrations and dormers this source does not detect add nothing to the score. Complexity policy v1 is a heuristic, not a calibrated rule; adjust for your cut style.
Waste applies to roof area only. Material rows use their stated coverage, allowances and purchase units; do not round these area figures into an order.
Eaves are level edges where water leaves the roof; rakes are sloped gable edges. Step flashing follows a wall up the slope; wall flashing runs across the top of a roof plane at a wall; a transition is a change of pitch that is neither a ridge nor a valley. Lines counts the separate lines drawn; a line two facets share is counted once.
Plan sheet A-101 rev C · Materials
Material estimate
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
| Product | Coverage | Order unit | Waste 0% | Waste 10% | RecommendedWaste 12% | Waste 15% |
|---|---|---|---|---|---|---|
| Shingles (pitched area + waste) | 4,443 sq ft | 4,887 sq ft | 4,976 sq ft | 5,109 sq ft | ||
| IKO — Cambridge | 33.33 sq ft | bundle | 134 | 147 | 150 | 154 |
| CertainTeed — Landmark | 32.8 sq ft | bundle | 136 | 149 | 152 | 156 |
| GAF — Timberline HDZ | 33.33 sq ft | bundle | 134 | 147 | 150 | 154 |
| Owens Corning — Duration | 32.8 sq ft | bundle | 136 | 149 | 152 | 156 |
| BP — Mystique 42 | 32.9 sq ft | bundle | 136 | 149 | 152 | 156 |
| Starter (eaves + rakes) | 393' 1" | 393' 1" | 393' 1" | 393' 1" | ||
| IKO — Leading Edge Plus | 109 ft | bundle | 4 | 4 | 4 | 4 |
| CertainTeed — SwiftStart | 116 ft | bundle | 4 | 4 | 4 | 4 |
| GAF — Pro-Start | 120.33 ft | bundle | 4 | 4 | 4 | 4 |
| Owens Corning — Starter Strip Plus | 105 ft | bundle | 4 | 4 | 4 | 4 |
| BP — Starter Strip | 69 ft | bundle | 6 | 6 | 6 | 6 |
| Underlayment (pitched area) | 4,443 sq ft | 4,443 sq ft | 4,443 sq ft | 4,443 sq ft | ||
| IKO — Stormtite | 914.83 sq ft | roll | 5 | 5 | 5 | 5 |
| CertainTeed — RoofRunner | 937.5 sq ft | roll | 5 | 5 | 5 | 5 |
| GAF — Deck-Armor | 914.83 sq ft | roll | 5 | 5 | 5 | 5 |
| Owens Corning — RhinoRoof U20 | 904.08 sq ft | roll | 5 | 5 | 5 | 5 |
| BP — ProDeck | 914.22 sq ft | roll | 5 | 5 | 5 | 5 |
| Ice and water (eaves, valleys, walls) | 1,000 sq ft | 1,000 sq ft | 1,000 sq ft | 1,000 sq ft | ||
| IKO — StormShield | 193.5 sq ft | roll | 6 | 6 | 6 | 6 |
| CertainTeed — WinterGuard Granular | 193.5 sq ft | roll | 6 | 6 | 6 | 6 |
| GAF — WeatherWatch | 198.6 sq ft | roll | 6 | 6 | 6 | 6 |
| Owens Corning — WeatherLock G | 198.6 sq ft | roll | 6 | 6 | 6 | 6 |
| BP — Weathertex | 193.5 sq ft | roll | 6 | 6 | 6 | 6 |
| Hip and ridge cap (hips + ridges) | 189' 10" | 189' 10" | 189' 10" | 189' 10" | ||
| IKO — Hip and Ridge 12 | 29.53 ft | bundle | 7 | 7 | 7 | 7 |
| CertainTeed — Shadow Ridge | 30 ft | bundle | 7 | 7 | 7 | 7 |
| GAF — Seal-A-Ridge | 25 ft | bundle | 8 | 8 | 8 | 8 |
| Owens Corning — DecoRidge | 20 ft | box | 10 | 10 | 10 | 10 |
| BP — White Cap hip and ridge (1-ply) | 29.6 ft | box | 7 | 7 | 7 | 7 |
| Drip edge (eaves + rakes) | 393' 1" | 393' 1" | 393' 1" | 393' 1" | ||
| Generic — Drip edge, 10 ft | 9.5 ft | piece | 42 | 42 | 42 | 42 |
| Valley metal (valleys) | 46' 0" | 46' 0" | 46' 0" | 46' 0" | ||
| Generic — W-valley, 10 ft | 9.5 ft | piece | 5 | 5 | 5 | 5 |
Continued on the next page
Plan sheet A-101 rev C · Materials
Material estimate (continued)
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
| Product | Coverage | Order unit | Waste 0% | Waste 10% | RecommendedWaste 12% | Waste 15% |
|---|---|---|---|---|---|---|
| Step flashing (sidewalls) | 9' 6" | 9' 6" | 9' 6" | 9' 6" | ||
| Generic — Step flashing 4 × 4 × 8 in | 2.13 per ft | piece | 21 | 21 | 21 | 21 |
| Headwall flashing (apron) | 42' 0" | 42' 0" | 42' 0" | 42' 0" | ||
| Generic — Headwall (apron) flashing, 10 ft | 9.5 ft | piece | 5 | 5 | 5 | 5 |
| Counter flashing (walls) | 51' 6" | 51' 6" | 51' 6" | 51' 6" | ||
| Generic — Counter flashing, 10 ft | 9.5 ft | piece | 6 | 6 | 6 | 6 |
| Ridge vent (ridges less end setbacks) | 60' 9" | 60' 9" | 60' 9" | 60' 9" | ||
| Generic — Ridge vent, 4 ft | 4 ft | piece | 16 | 16 | 16 | 16 |
| Coil nails (shingle area + waste) | 4,443 sq ft | 4,887 sq ft | 4,976 sq ft | 5,109 sq ft | ||
| Generic — Coil nails, 1-1/4 in | 1,875 sq ft | box | 3 | 3 | 3 | 3 |
| Cap nails (underlayment area) | 4,443 sq ft | 4,443 sq ft | 4,443 sq ft | 4,443 sq ft | ||
| Generic — Plastic cap nails, 1 in | 3,000 sq ft | box | 2 | 2 | 2 | 2 |
| Sealant (flashing laps) | 51' 6" | 51' 6" | 51' 6" | 51' 6" | ||
| Generic — Roofing sealant, 10 oz tube | 25 ft | each | 3 | 3 | 3 | 3 |
Plan sheet A-101 rev C · Materials
Material estimate — notes (continued)
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
| Not in the matrix | Why |
|---|---|
| Pipe boots | The plumbing vent count is unknown, so no boots are estimated — not zero boots. |
| Chimney flashing kits | The chimney count is unknown, so no kits are estimated — not zero kits. Count them on site. |
| Skylight flashing kits | The skylight count is unknown, so no kits are estimated — not zero kits. Count them on site. |
| Low-slope membrane | No roof area is below 2/12. |
How each group is measured
- Shingles: Pitched roof area 4,443 sq ft (2/12 and steeper) × (1 + waste).
- Starter: Eaves 261' 6" + rakes 112' 11" = 374' 5", plus 5% for end laps and corner cuts. The same in every waste column.
- Underlayment: Pitched roof area 4,443 sq ft. Laps are inside each roll's effective coverage; no waste is added. The same in every waste column.
- Ice and water: Eaves 261' 6" × 3 ft + valleys 46' 0" × 3 ft + walls 51' 6" × 1.5 ft = 1,000 sq ft. Estimate setting, not a code determination: one 3 ft course at the eaves, 3 ft centred on valleys and 18 in along walls. Confirm the jurisdiction and manufacturer requirement. The same in every waste column.
- Hip and ridge cap: Hips 123' 1" + ridges 66' 9" = 189' 10". The cap also covers any ridge vent; the vent is its own group, not a second cap line. The same in every waste column.
- Drip edge: Eaves 261' 6" + rakes 112' 11" = 374' 5", plus 5% for corner cuts. Each piece counts at its lapped length. The same in every waste column.
- Valley metal: Valleys 46' 0". Open valleys only; a closed-cut valley needs none. Each piece counts at its lapped length. The same in every waste column.
- Step flashing: Step-flashed walls 9' 6". One piece per shingle course. Headwall and counter flashing and the chimney and skylight kits are their own groups. The same in every waste column.
- Headwall flashing: Headwalls 42' 0". Apron flashing where a roof runs into a wall above it. Each piece counts at its lapped length. The same in every waste column.
- Counter flashing: Step-flashed walls 9' 6" + headwalls 42' 0" = 51' 6". Caps the step and apron flashing at a masonry wall; where siding laps the flashing none is needed. The wall material is not seen from the air: confirm it on site. The same in every waste column.
- Ridge vent: 3 ridge runs totalling 66' 9", less 1 ft at each end of each run = 60' 9". Every run is counted; a ventilation plan decides which are vented. The same in every waste column.
- Coil nails: Follows the field-shingle area including waste, because the nails fasten those shingles.
- Cap nails: Follows the underlayment area, 4,443 sq ft: cap nails fasten the underlayment, not the shingles, so waste does not buy them. The same in every waste column.
- Sealant: Step-flashed walls 9' 6" + headwalls 42' 0" = 51' 6": one bead along every flashing lap. Pipe boots and the chimney and skylight kits carry their own sealant. The same in every waste column.
The highlighted 12% column is the waste recommended from the roof's complexity score — a heuristic, not a calibrated rule.
Products in a group are alternatives: choose one per group. Rows are never added together (BOOK-07).
The waste percentage applies to field shingles and the nails that fasten them. Every other group uses its own allowance, the same in every column (BOOK-08).
Each quantity is rounded up once, at the pack, from the unrounded total; no intermediate whole-square rounding (MAT-06).
Coverage values are sample presets pending review (MAT-03). Verify coverage with current manufacturer literature before ordering.
Not included: labour, tear-off and disposal, decking repairs, permits, and any low-slope system until one is chosen.
Plan sheet A-101 rev C · Appendix
Edge ledger
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
41 lines, each counted once
| Line | Type | True length | Plan length | Facets | On drawing |
|---|---|---|---|---|---|
| E1 | Eaves | 40' 0" | 40' 0" | F3 | Labelled |
| E2 | Eaves | 30' 0" | 30' 0" | F2 | Labelled |
| E3 | Eaves | 28' 0" | 28' 0" | F6 | Labelled |
| E4 | Eaves | 24' 0" | 24' 0" | F1 | Labelled |
| E5 | Eaves | 24' 0" | 24' 0" | F2 | Labelled |
| E6 | Eaves | 20' 0" | 20' 0" | F4 | Labelled |
| E7 | Eaves | 18' 0" | 18' 0" | F5 | Labelled |
| E8 | Eaves | 18' 0" | 18' 0" | F5 | Labelled |
| E9 | Eaves | 18' 0" | 18' 0" | F10 | Labelled |
| E10 | Eaves | 10' 0" | 10' 0" | F5 | Labelled |
| E11 | Eaves | 10' 0" | 10' 0" | F2 | Labelled |
| E12 | Eaves | 8' 0" | 8' 0" | F7 | Labelled |
| E13 | Eaves | 6' 0" | 6' 0" | F8 | Labelled |
| E14 | Eaves | 6' 0" | 6' 0" | F9 | Labelled |
| E15 | Eaves | 1' 6" | 1' 6" | F5 | Listed only |
| E16 | Rakes | 16' 10" | 14' 0" | F6 | Labelled |
| E17 | Rakes | 16' 10" | 14' 0" | F6 | Labelled |
| E18 | Rakes | 16' 10" | 14' 0" | F7 | Labelled |
| E19 | Rakes | 12' 3" | 12' 0" | F1 | Labelled |
| E20 | Rakes | 12' 3" | 12' 0" | F1 | Labelled |
| E21 | Rakes | 12' 0" | 10' 0" | F7 | Labelled |
| E22 | Rakes | 9' 1" | 7' 0" | F9 | Labelled |
| E23 | Rakes | 9' 1" | 7' 0" | F8 | Labelled |
| E24 | Rakes | 6' 2" | 6' 0" | F10 | Labelled |
| E25 | Rakes | 1' 6" | 1' 3" | F7 | Listed only |
| E26 | Ridges | 28' 0" | 28' 0" | F6, F7 | Labelled |
| E27 | Ridges | 24' 0" | 24' 0" | F2, F5 | Labelled |
| E28 | Ridges | 14' 9" | 14' 9" | F8, F9 | Labelled |
| E29 | Hips | 31' 3" | 28' 3" | F2, F3 | Labelled |
| E30 | Hips | 31' 3" | 28' 3" | F2, F4 | Labelled |
| E31 | Hips | 31' 3" | 28' 3" | F3, F5 | Labelled |
| E32 | Hips | 29' 4" | 26' 6" | F4, F5 | Labelled |
| E33 | Valleys | 18' 9" | 18' 9" | F4, F7 | Labelled |
| E34 | Valleys | 12' 8" | 11' 2" | F5, F9 | Labelled |
| E35 | Valleys | 12' 8" | 11' 2" | F5, F8 | Labelled |
Shared lines such as ridges, hips and valleys appear once and list both facets. Skylight kits are shown for completeness and are not roof line totals.
Continued on the next page
Plan sheet A-101 rev C · Appendix
Edge ledger (continued)
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
41 lines, each counted once
| Line | Type | True length | Plan length | Facets | On drawing |
|---|---|---|---|---|---|
| E36 | Valleys | 1' 11" | 1' 9" | F5, F7 | Listed only |
| E37 | Step flashing | 6' 2" | 6' 0" | F10 | Labelled |
| E38 | Step flashing | 1' 10" | 1' 6" | F7 | Listed only |
| E39 | Step flashing | 1' 6" | 1' 3" | F4 | Listed only |
| E40 | Wall flashing | 24' 0" | 24' 0" | F1 | Labelled |
| E41 | Wall flashing | 18' 0" | 18' 0" | F10 | Labelled |
Shared lines such as ridges, hips and valleys appear once and list both facets. Skylight kits are shown for completeness and are not roof line totals.
Scope and sources
Scope, revision and source notes
Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built
Pitch and height sources (planned values from the elevations)
| Roof plane | Pitch | Pitch from | Eave | Eave from |
|---|---|---|---|---|
| Main hip roof | 8/12 | A-201 “8:12 TYP. U.N.O.” | 10' 0" | A-201 “PLATE HT. 10'-0" TYP.” |
| Garage gable | 8/12 | A-201 “8:12 AT GARAGE” | 9' 0" | A-201 “GARAGE PLATE 9'-0"” |
| Entry gable | 10/12 | A-201 “10:12 AT ENTRY GABLE” | 10' 0" | A-201 “PLATE HT. 10'-0" TYP.” |
| Front porch | 3/12 | A-201 “3:12 PORCH ROOF” | 8' 0" | A-201 “BEAM HT. 8'-0"” |
| Rear patio cover | 2.5/12 | A-201 “2 1/2:12 PATIO COVER” | 7' 0" | A-201 “BEAM HT. 7'-0"” |
Revision record
| Sheet | Rev | Date | Status |
|---|---|---|---|
| A-101 | C | Aug 14, 2026 | Current — measured from |
| A-101 | B | Jul 2, 2026 | Superseded: Garage widened to 28'-0" |
| A-101 | A | May 20, 2026 | Superseded: Issued for pricing |
| A-201 | C | Aug 14, 2026 | Current — measured from |
| A-201 | B | Jul 2, 2026 | Superseded: Entry gable raised to 10:12 |
| A-201 | A | May 20, 2026 | Superseded: Issued for pricing |
| A-501 | B | Jul 2, 2026 | Current — referenced only |
| A-501 | A | May 20, 2026 | Superseded: Issued for pricing |
Scope notes
- Measured from plans: the roof as drawn at the current revisions, not as built. Field-verify dimensions, pitches and heights before ordering.
- A superseded or revised plan produces a new report version with a new lock; this version stays reproducible under RL-E96247DC.
- Overhangs, returns and cornices follow the roof outline as drawn; detail sheets are referenced, not measured.
- Plan north is as drawn on A-101; it has not been checked against the site.
- An absent pitch or height is never assumed: a plane without its note stops the measurement.
This report
- Report
- RK-2026-0925-S11B-R11 · v1
- Generated
- Sep 25, 2026
- Geometry
- Roof outline traced on A-101 (roof-build v1)
- Calibration
- 2 dimensions, agreement 0.14%
- Revision lock
- RL-E96247DC
- Template
- report-book@1 · R11
- Plan set: Example Ranch Estates — Plan 2410 (synthetic plan set)
Limitations
- An invented plan set for a house that does not exist: not a real lot, plan or designer.
- Quantities describe the roof as drawn. Construction changes and field conditions are not visible in plans.
- Pitches and eave heights are the notes printed on the elevations; they are read, not measured.
- No accuracy or certification is claimed; field-verify before ordering.