Preview: check roof-data availability by address. Sample reports use synthetic data.Payments are in test mode.Read the sample report

Skip to main content
All sample reports
Sample property

Blueprint Takeoff

A roof measured from a calibrated plan set, with sheet references and a revision lock.

Lot 14, Example Ranch Estates, Prosper, TX 75078 (synthetic plan set, planned, not built). Made-up example data, not a measurement of a real home.

RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Blueprint takeoff

Blueprint Takeoff

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

Planned roof area
4,443 sq ft
Squares
44.43
Roof facets
10
Predominant pitch
8/12
from elevation notes
Calibration agreement
0.14%
within 0.5% tolerance
Three-dimensional view of the planned roof with 10 facets.
The planned roof, built from the calibrated plan. Walls for context only.

Plan set

Project
Lot 14, Example Ranch Estates, Prosper, TX 75078
Status
Planned, not built
Plan set
Example Ranch Estates — Plan 2410 (synthetic plan set)
Sheets
A-101 rev C, A-201 rev C, A-501 rev B
Revision lock
RL-E96247DC
Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 1 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan set

Drawing register and calibration

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

Planned roof area
4,443 sq ft
Squares
44.43
Roof facets
10
Predominant pitch
8/12
from elevation notes
Calibration agreement
0.14%
within 0.5% tolerance

Drawing register

SheetTitleScale as printedRevDateUsed for
A-101Roof plan1/8" = 1'-0"CAug 14, 2026Roof outline traced; scale calibrated
A-201Exterior elevations1/8" = 1'-0"CAug 14, 2026Pitch notes, eave heights
A-501Roof details3/4" = 1'-0"BJul 2, 2026Referenced for details; nothing measured from it

Scale calibration: two independent printed dimensions

DimensionSheetPrintedOn sheetScaleAt adoptedDeviation
CAL-1 · Overall depth along the west wallA-10140' 0"5.004 in1 in = 7.994 ft40' 0"+0.07%
CAL-2 · Garage width across the door wallA-10128' 0"3.498 in1 in = 8.005 ft28' 0"−0.07%

Scale comes only from printed dimensions measured on the traced sheet. A title-block scale note or an image resolution is recorded, never used; each sheet is calibrated on its own.

Plan of the traced roof with calibration dimensions CAL-1 and CAL-2 drawn where they were measured.CAL-1 · 40' 0"CAL-2 · 28' 0"
Roof outline traced on A-101 at the adopted scale, with the two printed dimensions that calibrate it.

Result

Status
Accepted — measurement allowed
Adopted scale
1 in = 7.999 ft
Agreement
0.14% (tolerance 0.50%)

Revision lock

Lock
RL-E96247DC
Calibration digest
663f65e7
  • Sheets: A-101/C@2026-08-14 A-201/C@2026-08-14 A-501/B@2026-07-02

The lock is built from each sheet id, revision and date plus a digest of the calibration. A superseded sheet or a new calibration changes it, and that produces a new report version.

Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 2 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Diagram

Roof diagram

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

Plan view of 10 roof facets.
Roof plan. Openings such as chimneys and skylights are drawn as holes and are not roof area.

Structures

  • Planned house and garage4,443 sq ft
Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 3 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Lengths

Length measurement report

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

  • Eaves261' 6"
  • Rakes112' 11"
  • Ridges66' 9"
  • Hips123' 1"
  • Valleys46' 0"
  • Step flashing9' 6"
  • Wall flashing42' 0"
  • Transitions0' 0"
  • Parapet walls0' 0"
Plan of every roof line, coloured by line type and labelled with its length in feet.40'30'31'31'31'28'28'29'24'24'24'24'20'19'18'18'18'18'15'17'17'17'12'12'13'13'10'12'10'8'9'9'6'6'6'6'2'

Labels show true 3D lengths rounded to the nearest foot. Totals above are summed unrounded and rounded once to the inch.

Flashing lines are drawn dotted. 4 short or crowded lines are not labelled here; every line is listed in the edge ledger.

Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 4 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Areas

Area measurement report

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

Total roof area
4,443 sq ft
Pitched roof area
4,443 sq ft
Low-slope area (below 2/12)
0 sq ft
Predominant pitch
8/12
Predominant pitch area
3,848 sq ft
Upper-story area
0 sq ft
Plan with the sloped area of each facet in square feet.1,0579824814714524062941119595

Areas are sloped (true surface) square feet, rounded to the nearest whole number on the drawing. The totals are sums of the unrounded facet areas.

Openings such as chimneys and skylights are deducted once; roof-mounted equipment is not deducted.

Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 5 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Pitch and direction

Pitch and direction

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

Plan with the pitch of each facet and an arrow pointing down the slope.8/128/128/128/128/128/123/123/1210/1210/12

Area by pitch

  • 8/123,848 sq ft · 87%
  • 3/12405 sq ft · 9%
  • 10/12189 sq ft · 4%

Steepness

  • 2/12 – 3/12
  • 8/12 – 9/12
  • 10/12 – 11/12

Pitch is shown to the nearest whole rise over 12; areas and classes use the unrounded pitch. Arrows point down the slope, the way water runs.

Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 6 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Facets

Facet ledger

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

Plan with every facet numbered to match the facet table.12345678910
Numbers match the table rows.

Facets 1–10 of 10

#LevelPitchFacesArea sq ft% roof
1Main3/12N2946.6%
2Main8/12N1,05723.8%
3Main8/12W48110.8%
4Main8/12E45210.2%
5Main8/12S98222.1%
6Main8/12E47110.6%
7Main8/12W4069.1%
8Main10/12W952.1%
9Main10/12E952.1%
10Main3/12S1112.5%
Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 7 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Summary

Roof summary and waste

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

Small plan of the measured roof.

Measurements

Total roof area
4,443 sq ft
Pitched area
4,443 sq ft
Low-slope area
0 sq ft
Roof facets
10
Predominant pitch
8/12
Eaves
261' 6"
Rakes
112' 11"
Ridges
66' 9"
Hips
123' 1"
Valleys
46' 0"
Step flashing
9' 6"
Wall flashing
42' 0"
Transitions
0' 0"
Hips + ridges
189' 10"
Eaves + rakes
374' 5"

Area by pitch

Pitch8/123/1210/12
Area (sq ft)3,848405189
Squares38.484.051.89
Share87%9%4%

Waste scenarios

Waste0%10%Recommended12%15%17%20%25%
Area (sq ft)4,4434,8874,9765,1095,1985,3315,553
Squares44.4348.8749.7651.0951.9853.3155.53

Recommended 12% from complexity policy v1: rated moderate (45 of 100 points). A heuristic, not a calibrated rule; adjust for your cut style.

Waste applies to the roof area only. Starter, caps, ridge and valley materials have their own allowances on the material estimate.

Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 8 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Materials

Material estimate

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

ProductCoverageUnitWaste 0%Waste 10%RecommendedWaste 12%Waste 15%
Shingles (pitched area + waste)4,443 sq ft4,887 sq ft4,976 sq ft5,109 sq ft
IKO — Cambridge33.3 sq ftbundle134147150154
CertainTeed — Landmark32.8 sq ftbundle136149152156
GAF — Timberline HDZ33.3 sq ftbundle134147150154
Owens Corning — Duration32.8 sq ftbundle136149152156
BP — Mystique 4232.9 sq ftbundle136149152156
Starter (eaves + rakes)393' 1"393' 1"393' 1"393' 1"
IKO — Leading Edge Plus109 ftbundle4444
CertainTeed — SwiftStart116 ftbundle4444
GAF — Pro-Start120.33 ftbundle4444
Owens Corning — Starter Strip Plus105 ftbundle4444
BP — Starter Strip69 ftbundle6666
Underlayment (pitched area)4,443 sq ft4,443 sq ft4,443 sq ft4,443 sq ft
IKO — Stormtite914.8 sq ftroll5555
CertainTeed — RoofRunner937.5 sq ftroll5555
GAF — Deck-Armor914.8 sq ftroll5555
Owens Corning — RhinoRoof U20904.1 sq ftroll5555
BP — ProDeck914.2 sq ftroll5555
Ice and water (eaves, valleys, walls)1,000 sq ft1,000 sq ft1,000 sq ft1,000 sq ft
IKO — StormShield193.5 sq ftroll6666
CertainTeed — WinterGuard Granular193.5 sq ftroll6666
GAF — WeatherWatch198.6 sq ftroll6666
Owens Corning — WeatherLock G198.6 sq ftroll6666
BP — Weathertex193.5 sq ftroll6666
Hip and ridge cap (hips + ridges)189' 10"189' 10"189' 10"189' 10"
IKO — Hip and Ridge 1229.53 ftbundle7777
CertainTeed — Shadow Ridge30 ftbundle7777
GAF — Seal-A-Ridge25 ftbundle8888
Owens Corning — DecoRidge20 ftbox10101010
BP — White Cap hip and ridge (1-ply)29.6 ftbox7777
Drip edge (eaves + rakes)393' 1"393' 1"393' 1"393' 1"
Generic — Drip edge, 10 ft9.5 ftpiece42424242
Valley metal (valleys)46' 0"46' 0"46' 0"46' 0"
Generic — W-valley, 10 ft9.5 ftpiece5555

Continued on next page →

Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 9 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Materials

Material estimate (continued)

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

ProductCoverageUnitWaste 0%Waste 10%RecommendedWaste 12%Waste 15%
Step flashing (sidewalls)9' 6"9' 6"9' 6"9' 6"
Generic — Step flashing 4 × 4 × 8 in2.13 per ftpiece21212121
Ridge vent (ridges less end setbacks)60' 9"60' 9"60' 9"60' 9"
Generic — Ridge vent, 4 ft4 ftpiece16161616
Coil nails (shingle area + waste)4,443 sq ft4,887 sq ft4,976 sq ft5,109 sq ft
Generic — Coil nails, 1-1/4 in1,875 sq ftbox3333
Not in the matrixWhy
Pipe bootsThe plumbing vent count is unknown, so no boots are estimated — not zero boots.
Low-slope membraneNo roof area is below 2/12.

How each group is measured

  • Shingles: Pitched roof area 4,443 sq ft (2/12 and steeper) × (1 + waste).
  • Starter: Eaves 261' 6" + rakes 112' 11" = 374' 5", plus 5% for end laps and corner cuts. The same in every waste column.
  • Underlayment: Pitched roof area 4,443 sq ft. Laps are inside each roll's effective coverage; no waste is added. The same in every waste column.
  • Ice and water: Eaves 261' 6" × 3 ft + valleys 46' 0" × 3 ft + walls 51' 6" × 1.5 ft = 1,000 sq ft. Estimate setting, not a code determination: one 3 ft course at the eaves, 3 ft centred on valleys and 18 in along walls. Confirm the jurisdiction and manufacturer requirement. The same in every waste column.
  • Hip and ridge cap: Hips 123' 1" + ridges 66' 9" = 189' 10". The cap also covers any ridge vent; the vent is its own group, not a second cap line. The same in every waste column.
  • Drip edge: Eaves 261' 6" + rakes 112' 11" = 374' 5", plus 5% for corner cuts. Each piece counts at its lapped length. The same in every waste column.
  • Valley metal: Valleys 46' 0". Open valleys only; a closed-cut valley needs none. Each piece counts at its lapped length. The same in every waste column.
  • Step flashing: Step-flashed walls 9' 6". One piece per shingle course. Headwall, chimney and skylight flashing are not in this matrix. The same in every waste column.
  • Ridge vent: 3 ridge runs totalling 66' 9", less 1 ft at each end of each run = 60' 9". Every run is counted; a ventilation plan decides which are vented. The same in every waste column.
  • Coil nails: Follows the field-shingle area including waste, because the nails fasten those shingles.

The highlighted 12% column is the waste recommended from the roof's complexity score — a heuristic, not a calibrated rule.

Products in a group are alternatives: choose one per group. Rows are never added together (BOOK-07).

The waste percentage applies to field shingles and the nails that fasten them. Every other group uses its own allowance, the same in every column (BOOK-08).

Each quantity is rounded up once, at the pack, from the unrounded total; no intermediate whole-square rounding (MAT-06).

Coverage values are sample presets pending review (MAT-03). Verify coverage with current manufacturer literature before ordering.

Not included: labour, tear-off and disposal, decking repairs, permits, and any low-slope system until one is chosen.

Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 10 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Appendix

Edge ledger

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

41 lines, each counted once

LineTypeTrue lengthPlan lengthFacetsOn drawing
E1Eaves40' 0"40' 0"F3Labelled
E2Eaves30' 0"30' 0"F2Labelled
E3Eaves28' 0"28' 0"F6Labelled
E4Eaves24' 0"24' 0"F1Labelled
E5Eaves24' 0"24' 0"F2Labelled
E6Eaves20' 0"20' 0"F4Labelled
E7Eaves18' 0"18' 0"F5Labelled
E8Eaves18' 0"18' 0"F5Labelled
E9Eaves18' 0"18' 0"F10Labelled
E10Eaves10' 0"10' 0"F5Labelled
E11Eaves10' 0"10' 0"F2Labelled
E12Eaves8' 0"8' 0"F7Labelled
E13Eaves6' 0"6' 0"F8Labelled
E14Eaves6' 0"6' 0"F9Labelled
E15Eaves1' 6"1' 6"F5Listed only
E16Rakes16' 10"14' 0"F6Labelled
E17Rakes16' 10"14' 0"F6Labelled
E18Rakes16' 10"14' 0"F7Labelled
E19Rakes12' 3"12' 0"F1Labelled
E20Rakes12' 3"12' 0"F1Labelled
E21Rakes12' 0"10' 0"F7Labelled
E22Rakes9' 1"7' 0"F9Labelled
E23Rakes9' 1"7' 0"F8Labelled
E24Rakes6' 2"6' 0"F10Labelled
E25Rakes1' 6"1' 3"F7Listed only
E26Ridges28' 0"28' 0"F6, F7Labelled
E27Ridges24' 0"24' 0"F2, F5Labelled
E28Ridges14' 9"14' 9"F8, F9Labelled
E29Hips31' 3"28' 3"F2, F3Labelled
E30Hips31' 3"28' 3"F2, F4Labelled
E31Hips31' 3"28' 3"F3, F5Labelled
E32Hips29' 4"26' 6"F4, F5Labelled
E33Valleys18' 9"18' 9"F4, F7Labelled
E34Valleys12' 8"11' 2"F5, F9Labelled
E35Valleys12' 8"11' 2"F5, F8Labelled

Shared lines such as ridges, hips and valleys appear once and list both facets. Skylight kits are shown for completeness and are not roof line totals.

Continued on next page →

Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 11 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Plan sheet A-101 rev C · Appendix

Edge ledger (continued)

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

41 lines, each counted once

LineTypeTrue lengthPlan lengthFacetsOn drawing
E36Valleys1' 11"1' 9"F5, F7Labelled
E37Step flashing6' 2"6' 0"F10Labelled
E38Step flashing1' 10"1' 6"F7Listed only
E39Step flashing1' 6"1' 3"F4Listed only
E40Wall flashing24' 0"24' 0"F1Labelled
E41Wall flashing18' 0"18' 0"F10Labelled

Shared lines such as ridges, hips and valleys appear once and list both facets. Skylight kits are shown for completeness and are not roof line totals.

Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 12 of 13
RoofKarmaBlueprint Takeoff
RK-2026-0925-S11B-R11 · v1Sample — synthetic plan set

Scope and sources

Scope, revision and source notes

Lot 14, Example Ranch Estates, Prosper, TX 75078 — planned, not built

Pitch and height sources (planned values from the elevations)

Roof planePitchPitch fromEaveEave from
Main hip roof8/12A-201 “8:12 TYP. U.N.O.”10' 0"A-201 “PLATE HT. 10'-0" TYP.”
Garage gable8/12A-201 “8:12 AT GARAGE”9' 0"A-201 “GARAGE PLATE 9'-0"”
Entry gable10/12A-201 “10:12 AT ENTRY GABLE”10' 0"A-201 “PLATE HT. 10'-0" TYP.”
Front porch3/12A-201 “3:12 PORCH ROOF”8' 0"A-201 “BEAM HT. 8'-0"”
Rear patio cover2.5/12A-201 “2 1/2:12 PATIO COVER”7' 0"A-201 “BEAM HT. 7'-0"”

Revision record

SheetRevDateStatus
A-101CAug 14, 2026Current — measured from
A-101BJul 2, 2026Superseded: Garage widened to 28'-0"
A-101AMay 20, 2026Superseded: Issued for pricing
A-201CAug 14, 2026Current — measured from
A-201BJul 2, 2026Superseded: Entry gable raised to 10:12
A-201AMay 20, 2026Superseded: Issued for pricing
A-501BJul 2, 2026Current — referenced only
A-501AMay 20, 2026Superseded: Issued for pricing

Scope notes

  • Measured from plans: the roof as drawn at the current revisions, not as built. Field-verify dimensions, pitches and heights before ordering.
  • A superseded or revised plan produces a new report version with a new lock; this version stays reproducible under RL-E96247DC.
  • Overhangs, returns and cornices follow the roof outline as drawn; detail sheets are referenced, not measured.
  • Plan north is as drawn on A-101; it has not been checked against the site.
  • An absent pitch or height is never assumed: a plane without its note stops the measurement.

This report

Report
RK-2026-0925-S11B-R11 · v1
Generated
Sep 25, 2026
Geometry
Roof outline traced on A-101 (roof-build v1)
Calibration
2 dimensions, agreement 0.14%
Revision lock
RL-E96247DC
Template
report-book@1 · R11
  • Plan set: Example Ranch Estates — Plan 2410 (synthetic plan set)

Limitations

  • An invented plan set for a house that does not exist: not a real lot, plan or designer.
  • Quantities describe the roof as drawn. Construction changes and field conditions are not visible in plans.
  • Pitches and eave heights are the notes printed on the elevations; they are read, not measured.
  • No accuracy or certification is claimed; field-verify before ordering.
Synthetic sample plan set — planned, not built. Not a real property.RoofKarma · Blueprint TakeoffPage 13 of 13