Preview: check roof-data availability by address. Sample reports use synthetic data.Payments are in test mode.Read the sample report

Skip to main content
All sample reports
Sample property

Roof Details

Story breakdown, work zones, ventilation and codes. This view adds details without repeating the measurement sheets.

4100 Example Ridge Drive, Plano, TX 75024 (synthetic). Made-up example data, not a measurement of a real home.

RoofKarmaRoof Details
RK-2026-0925-S4R1-R3 · v1Sample — synthetic property

Additional roof planning details

Roof Details

4100 Example Ridge Drive, Plano, TX 75024

About this sample

Story breakdown, work zones, ventilation and codes. This view adds details without repeating the measurement sheets.

Read alongside Roof Measurements

The roof plan, facet and edge ledgers, dimensions and pitch sheets are published once in the Roof Measurements sample. Material Takeoff owns the complete quantity matrix.

These examples use synthetic data. Codes and ventilation assumptions require project-specific verification before installation.

Synthetic sample. Not a measurement of a real property.RoofKarma · Roof DetailsPage 1 of 6
RoofKarmaRoof Details
RK-2026-0925-S4R1-R3 · v1Sample — synthetic property

Premium · Levels

Story breakdown

4100 Example Ridge Drive, Plano, TX 75024

Main level
22.07 sq
2,207 sq ft · 7 facets
Upper level (2+ stories)
29.19 sq
2,919 sq ft · 10 facets
Plan shaded by the level each roof facet sits on.
LevelFacetsArea sq ftSquaresShare
Main level72,20722.0743%
Upper level (2+ stories)102,91929.1957%
  • Main level
  • Upper level (2+ stories)

Level comes from the eave height of each roof section. Upper-level roofs usually need more staging and safety equipment; price them accordingly.

Synthetic sample. Not a measurement of a real property.RoofKarma · Roof DetailsPage 2 of 6
RoofKarmaRoof Details
RK-2026-0925-S4R1-R3 · v1Sample — synthetic property

Premium · Work zones

Pitch zones and complexity hotspots

4100 Example Ridge Drive, Plano, TX 75024

Plan shaded by pitch band with complexity hotspots marked.
Triangles mark valleys and wall-flashing lines: the cut-and-flash hotspots.

Roof area by pitch band

  • Low slope (below 4/12)272 sq ft · 5%
  • Walkable pitch (4/12 to below 7/12)1,935 sq ft · 38%
  • Steep (7/12 to below 10/12)2,919 sq ft · 57%

Hotspots

  • 6 valleys to cut and line with ice and water barrier.
  • 20 wall-flashing lines where roofs meet walls, dormers or the chimney.
  • 6 distinct pitches; each change is a cut line.

Pitch bands follow the 05 §4.1 classes on unrounded pitch. They describe the roof, not a safety rating; follow your own fall-protection plan.

Synthetic sample. Not a measurement of a real property.RoofKarma · Roof DetailsPage 3 of 6
RoofKarmaRoof Details
RK-2026-0925-S4R1-R3 · v1Sample — synthetic property

Premium · Ventilation

Attic ventilation

4100 Example Ridge Drive, Plano, TX 75024

Attic floor
4,096 sq ft
plan area, not roof surface
Net free area required
1,966 sq in
1/300 of the attic floor
Exhaust / intake
983 / 983 sq in
50% high · 50% low
Ridge / eave available
77' / 364'
usable runs
Roof plan with ridge-vent runs highlighted along the ridges, stopping short of each end, and intake marked along the eaves over the attic.
Placement plan: vents are laid along these runs; exact positions are set on site.
  • Ridge vent runs76' 10"
  • Intake at eaves363' 11"
  • Open cover — no attic below

Exhaust (high) — 983 sq in required

ProductNet free areaQuantityProvidesRun allowsStatus
Shingle-over ridge vent, 4 ft18 sq in/ft · 4' pieces14 pieces1,008 sq in1,383 sq inSufficient
Static box vent (roof louver)50 sq in each20 each1,000 sq inNo run limitSufficient

Products are alternatives: use one per position, never add them together.

Intake (low) — 983 sq in required

ProductNet free areaQuantityProvidesRun allowsStatus
Continuous soffit vent, 8 ft strips9 sq in/ft · 8' pieces14 pieces1,008 sq in3,276 sq inSufficient
Vented drip edge, 10 ft pieces9 sq in/ft · 10' pieces11 pieces990 sq in3,276 sq inSufficient

Products are alternatives: use one per position, never add them together.

IRC 2021 R806.2 exception: 1/300 of the attic floor, 4,096 sq ft × 144 ÷ 300 = 1,966 sq in of net free area. Sample assumption: ridge exhaust supplies 50% of the required area within 3 ft of the ridge and eave intake the rest, and the vapor-retarder condition is treated as not applicable (it applies in climate zones 6–8). A real report records the adopted code edition, local amendments and climate zone.

Exhaust 50% high on the roof, intake the rest at the eaves.

Products at one position are alternatives; use one exhaust type per attic, since mixing ridge and box vents can short-circuit the airflow.

Keep intake at or above exhaust so the exhaust draws air in through the eaves.

Net free area values are sample presets pending review; use the chosen product’s published NFA.

With the highlighted products, intake is at least equal to exhaust.

Attic floor: plan area of the roofs over the attic, 4,096 sq ft; open porch and patio covers (398 sq ft) have no attic. Synthetic sample geometry.

Intake run: eaves over the attic, 363' 11"; dormer ridges and open-cover eaves are not used.

Synthetic sample. Not a measurement of a real property.RoofKarma · Roof DetailsPage 4 of 6
RoofKarmaRoof Details
RK-2026-0925-S4R1-R3 · v1Sample — synthetic property

Premium · Codes and climate

Building codes and climate

4100 Example Ridge Drive, Plano, TX 75024

Plano, TX (fictional sample address) · 2021 IRC as locally adopted — illustrative

Climate zone
3A (warm, humid)
Design wind
115 mph (illustrative)
Ground snow
5 psf (illustrative)
Rainfall intensity
3.8 in/hr (illustrative)
Hail exposure
High — North Texas hail region

Roofing requirements to confirm with the building department

TopicRequirementReference
UnderlaymentRequired under asphalt shingles; two layers where the slope is 2/12 to less than 4/12.IRC R905.1.1
Minimum slopeAsphalt shingles only on slopes of 2/12 or greater.IRC R905.2.2
Drip edgeRequired at eaves and rake edges of shingle roofs.IRC R905.2.8.5
ValleysValley lining per the code options or the shingle manufacturer’s instructions.IRC R905.2.8.2
Sidewall flashingStep flashing where the roof meets a sidewall, at least 4 in by 4 in.IRC R905.2.8.3
Wind resistanceShingles classified for the design wind speed (ASTM D7158 or D3161).IRC R905.2.4.1
Attic ventilationNet free area 1/150 of the vented space, or 1/300 when the conditions in the section are met.IRC R806.2
ReroofingNo recover over two or more existing layers; tear off to the deck.IRC R908.3.1.1
Synthetic sample. Not a measurement of a real property.RoofKarma · Roof DetailsPage 5 of 6
RoofKarmaRoof Details
RK-2026-0925-S4R1-R3 · v1Sample — synthetic property

Sources and limitations

Evidence, checks and limitations

4100 Example Ridge Drive, Plano, TX 75024

This report

Report
RK-2026-0925-S4R1-R3 · v1
Generated
Sep 25, 2026
Measurement grade
A — Sample grade
Imagery date
Mar 1, 2026
Geometry
RoofKarma synthetic massing model (roof-build v1)
Calculation
roof-analysis v1 · complexity-policy-v1
Template
report-book@1 · R3

Why this grade

Shown as grade A to demonstrate a complete report. A real report is graded from its source quality, obstruction and automated checks; grade D withholds prices and orderable quantities.

Automated quality checks

Automated checkResultDetail
Every facet closesPassedAll 17 facets are closed planar polygons.
Every line is classifiedPassedNo unclassified line; each is an eave, rake, ridge, hip, valley or flashing line.
Shared lines counted oncePassedRidges, hips and valleys shared by two facets are single lines in every total.
Pitch within 0/12 to 24/12PassedEvery facet pitch is within the modelled range.
Totals recompute exactlyPassedFacet areas sum to 5,125 sq ft before display rounding.
Structures in scopeNoteDetached workshop not included in totals (selectable).
SourceNoteSynthetic sample geometry. A real report states its imagery source, date and quality here.

Check at the property

  • Confirm valley and wall-flashing lengths where lower roofs meet walls.
  • Check chimney and skylight flashing condition and whether kits will be replaced.
  • Count vents and pipe boots; the drawing shows what is visible from above.
  • Confirm tear-off layers and decking before finalising the order.

Limitations

  • Every figure in this sample comes from an invented house built to exercise the report; it is not a surveyed property.
  • Measurements come from above: wall heights, decking condition and the number of layers are not visible from the air.
  • No accuracy or certification is claimed; a roofer confirms quantities on site before ordering.
Synthetic sample. Not a measurement of a real property.RoofKarma · Roof DetailsPage 6 of 6